Calibration of 1 ATMON FL module
Calibration of 1 ATMON FL module
Calibration of 1 ATMON FL module
Calibration of 1 ATMON FL module
Calibration of 1 ATMON FL module
Calibration of 1 ATMON FL module

Calibration of 1 ATMON FL module

  • Place the number of modules you own in the shopping basket
Regular price net incl. VAT / usł.
43,52 €
net / usł.
53,53 €
incl. VAT / usł.
You can also buy using:
This product is not available in a stationary store
Safe shopping
Product sold out
You will receive an email notification from us when the product is available again.
Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
Contact details entered above are not used to send newsletters or other advertisements. When you sign up to be notified, you hereby agree to receive only a one-time notification of a product re-availability.

Calibration of 1 ATMON FL module

Professional, take care of your equipment!



A reminder! Periodic inspections of the ATMON FL measuring modules should be performed every 6 months, but at least once a year!

The Nanosens specialists guarantee the highest quality of calibration of your measuring instruments, thanks to their many years of experience and vast practical knowledge. Internationally proven procedures and a standardised operating programme ensure that each calibration carried out is guaranteed to be consistent and measurement coherent.

By default, on this page you can request calibrations for 1 module. If you have more, please add as many to your basket as many measuring modules you have.



All available measuring modules ATMON FL:
- NH3 - ammonia
- HCL - hydrogen chloride
- CL2 - chlorine
- HCN - hydrogen cyanide
- NO2 - nitrogen dioxide
- SO2 - sulphur dioxide
- CO2 - carbon dioxide
- C2H6O - ethanol
- HCHO - formaldehyde
- RI - respiratory irritant complex
- AQ - air quality complex
- VOC - volatile organic compounds
- O3 - ozone
- PM - particulate matter
- H2S - hydrogen sulphide
- NO - nitrogen oxide
- CO - carbon monoxide
- ATM-FL-BPM - sampling module




It's easy! Order a calibration (put the number of modules corresponding to your measurement modules in the basket) and send us your ATM-FL. After calibration, it will be sent back to the address you specified.

All technical inspections, maintenance and calibrations are performed by NANOSENS service, i.e. the manufacturer at his premises. This is done by a team of experienced service engineers, who are responsible for the creation of your ATMONA FL.

If you have any further questions, please contact us by email - aeroMind team.
If your equipment is under warranty, module calibration is essential to maintain it!

Shipping address:
aeroMind - service ATMON FL
112B Piątkowska St.
60-649 Poznań

Price includes packaging and return shipping.



Detailed activities constituting the service:


1. diagnostics:
a) general inspection of the technical condition of the device
b) evaluation of external mechanical damage, if any - before starting up the
device
c) checking the readings of the appliance after switching it on, before carrying out further service work
d) assessment of the condition of the appliance's internal modules (water, corrosion, wear and tear of
mechanical components)
e) maintenance and cleaning of the above mentioned modules and elements
f) checking the operating parameters of the customer's power supply
g) checking the parameters of the power supply system, charging and battery consumption (full cycle
g) checking the parameters of the power supply, charging and battery consumption (full battery working cycle - 2x fully charged and fully discharged)
(h) status evaluation and technical parameter check of individual gas sensors
(i) software update of the control processor, if necessary


2. calibration:
(a) checking the response of the sensor to the reference gases
(b) adjustment of the characteristics of the individual sensors
(c) final calibration of sensor sensitivity with calibration gas


3. replacement of the sensor: is carried out when the sensor is worn out or its parameters significantly
sensor is worn out or its parameters differ considerably from the required ones (e.g. due to working in the concentration range not intended
range)
(a) Evaluation based on:
- initial analysis of sensor parameters as a result of inspection during the diagnostic process
- operating parameters of the sensor deviating from the standard in the sensor test carried out in the
the calibration process
b) Installation of a new sensor and carrying out stabilisation of the sensor (time for
stabilisation of the sensor parameters under operating conditions)
(c) checking the sensor parameters within the above mentioned period 1-3 times, depending on the sensor
(d) calibrating with reference gases


4. service repair of faults detected in the diagnostic process other than:
(a) sensor wear or damage
(b) soiling requiring standard cleaning without the use of additional cleaning and maintenance agents
cleaning and maintenance agents

The repair shall be commenced upon the acceptance by the customer of the submitted repair costs service.
Each service repair invoice is accompanied by a service protocol specifying the scope of the performed actions, used elements, subassemblies.

Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
Write your opinion
Your opinion:
5/5
Add your own product photo:
This page uses cookie files to provide its services in accordance to Cookies Usage Policy. You can determine conditions of storing or access to cookie files in your web browser.
Close
pixel