Easy product returns
Buy a product and check it in your own time, at home.
You can return the product without providing a reason within 14 days.
Show details
You can return the product without providing a reason within 14 days.
14 days to withdraw from the contract
Your satisfaction is very important to us, therefore you can make a return without providing a reason within
14
days.
No stress and worry
Thanks to the integration with cheap returns you can purchase without stress and be sure that the return process will be hassle free.
Easy returns wizard
All returns processed by our shop are managed in a easy-to-use returns wizard which gives you the ability to send a return parcel.
This product is available in our stores
You can buy this product without placing an online order at one of our stores in your area. Check where the product is in stock.
Check availability
Options for individual configuration of ATMON FL with any measured substances
ATMON-FL Air pollution analyzer (without media measurement modules) |
ATM-FL-AQ indicator of general air quality AQ: 0-100 ppm; accuracy: 0,05 ppm; resolution: 0,01 ppm |
ATM-FL-C2H6O C2H6O ethanol metering module: 0-500 ppm; accuracy: 0,3 ppm; resolution: 0,01 ppm |
ATM-FL-Cl2 Chlorine measurement module Cl2: 0-5 ppm; accuracy: 0,02 ppm; resolution: 0,01 ppm |
ATM-FL-CO Carbon monoxide measurement module CO: 0-1000 ppm; accuracy: 0,5 ppm; resolution: 0,1 ppm |
ATM-FL-CO2 Carbon dioxide measuring module CO2: 0-5000 ppm; accuracy: 50 ppm; resolution: 1 ppm |
ATM-FL-H2S Hydrogen sulfide measurement module H2S: 0-50 ppm; accuracy: 0,1 ppm; resolution: 0,01 ppm |
ATM-FL-HCHO Formaldehyde measurement module HCHO: 0-5 ppm; accuracy: 0,1 ppm; resolution: 0,01 ppm |
ATM-FL-HCL Hydrogen chloride measuring module HCL: 0-20 ppm; accuracy: 0,02 ppm; resolution: 0,01 ppm |
ATM-FL-HCN Hydrogen cyanide measuring module HCN: 0-100 ppm; accuracy: 0,1 ppm; resolution: 0,01 ppm |
ATM-FL-LZO Measurement module of volatile organic compounds VOC: 0-40 ppm; accuracy: 0,04 ppm; resolution: 0,01 ppm |
ATM-FL-NH3 Ammonia measuring module NH3: 0-100 ppm; accuracy: 1 ppm; resolution: 0,01 ppm |
ATM-FL-NO2 Nitrogen dioxide measurement module NO2: 0-5 ppm; accuracy: 0,02 ppm; resolution: 0,01 ppm |
ATM-FL-NO Nitric oxide measurement module NO: 0-100 ppm; accuracy: 0,1 ppm; resolution: 0,01 ppm |
ATM-FL-O3 Ozone measurement module O3: 0-2 ppm; accuracy: 0,02 ppm; resolution: 0,01 ppm |
ATM-FL-PM Dust measurement module PM10 / PM2.5: 0-999 ug/m3; accuracy: 15 ug/m3; resolution: 1 ug/m3 |
ATM-FL-RI Irritating substances in the respiratory tract RI: 0-20 ppm; accuracy: 0,02 ppm; resolution: 0,01 ppm |
ATM-FL-SO2 Sulfur dioxide measurement module SO2: 0-20 ppm; accuracy: 0,02 ppm; resolution: 0,01 ppm |
Set include:
- air pollution analyser (without measuring modules for gas and dust media)
- the set does not include a drone and camera shown in the pictures
Specification
POWER SUPPLY | Lithium-Polymer battery, 1S | ||
FULL CHARGING TIME | ~2,5h | ||
SAMPLE COLLECTION | Forced, electric | ||
REACTION TIME | < 30 s | ||
ATMON BATTERY LIFE H520 UAV |
< 5 h on single charge |
||
ATMON FLIGHT TIME | ~ 20 min | ||
Max range | 1600 m | ||
|
20% – 95% RH -20°C - + 50°C 800 mbar – 1150 mbar |
||
DIMENSIONS | Ø of enclosure max 125 mm OVERALL DEVICE HEIGHT max 115 mm |
||
WEIGHT | < 300 g | ||
AERODYNAMI ECNCLOSURE | HIPS – high impact polystyrene |
INTRODUCTION to ATMON FL - gas/pollution detector for Yuneec H520/H520E drones
How to Configure and use ATMON FL - gas/pollution detector for Yuneec H520/H520E drones
Users reviews
12 miesięcy - Warranty is granted by the seller for a period of 12 months.
12 miesięcy